NV3 elements – fibre cement, high-pressure laminate (HPL), ceramic, thin stone etc. Horizontal NVELOPE channel profiles are fixed to the vertical profiles. Rainscreen panels are hung from and secured with hangers.
NV3 is the NVELOPE system for concealed fix/mechanically fixed applications – vertical cladding applications.
Secured using hangers and undercut stud anchors or screws to provide a concealed fixing.
Horizontal NVELOPE channel profiles are fixed to the vertical profiles. Rainscreen panels are hung from and secured to the horizontal profiles with hangers and adjustable hangers.
NVELOPE 'T' and 'L' profiles are fixed using NVELOPE support brackets, fixed through a series of fixed and flexible points.
NVELOPE fixed point brackets absorb both vertical dead loads.
NVELOPE bracket spacing is determined by cladding options such as the dimensions and weight of the façade cladding, local wind loads.
NVELOPE flexible point brackets absorb wind loading and allow for expansion and contraction.
Material:
Manufactured from extruded aluminium alloys conforming to EN 573-3 (material) and EN 755 production standards.
Approvals:
British Board of Agrément (BBA) - 09/4678
Options:
NVELOPE brackets (V): allows adjustment between the face of the primary support to outer face of vertical profile. Thermal isolators: hard PVC isolator assembled as standard (located between the NVELOPE bracket and the primary structural support system).
Download NV3 technical spec here
Download NV3 Installer guide here
Download NV3 Hangers guide here
NV3 = NV1 + NV3 Components (mechanical concealed fix) |
||||
Select NV1 components (bracket and rail) - then - select NV3 components |
||||
Component |
Reference |
Detail |
||
Main NV3 horizontal rail |
CP-NV3-3000 |
3000 = 3 metre length (can be 6 m) |
||
Adjustable hangers |
NV3-TU-S-ADJP |
NV3-KEIL-ADFG |
Either TU-S / or PTS or KEIL Supplied with an adjusting screw |
|
Fixed hangers |
NV3--TU-S-STAT |
NV3-KEIL-STAT |
||
Fixings |
||||
SR2 4.2 x 16 |
4.2-16 |
Rail to bracket |
||
SR2 4.8 x 19 |
4.2-19 |
Main horizontal rail to 50x50 2.2 L rail |
||
Hanger securing screw |
SN3 A-8 x 50 |
4.8mm x 50mm securing screw |
||
SFS TU-S (HPL) |
On request |
HPL/Board |
||
TERGO (Square) |
NV3 TER-ADJP/STAT |
Marley Board |
||
TERGO + (Round) |
NV3 TER-TEC ADJP/STAT |
Marley Tectiva |
||
PTS screws 11.5 |
PTS-60/11.5 |
HPL / board (10mm) |
||
PTS screws 14.5 |
PTS-60/14.5 |
HPL / board (13mm) |
||
Keil anchors |
On request |
Thin stone / ceramic / fibre cement |
Size (mm) |
Min (mm) |
Max (mm) |
40 |
73 |
93 |
60 |
88 |
128 |
90 |
118 |
158 |
120 |
148 |
188 |
150 |
178 |
218 |
180 |
208 |
248 |
210 |
238 |
278 |
240 |
268 |
308 |
270 |
298 |
338 |
300 |
328 |
368 |
6.5mm holes (suitable for steel and / or timber substrates) / 11mm holes (suitable for block / concrete substrates) Includes NV3 rail and hanger (26mm). NVELOPE isolators: Included as standard - if isolator not required reduce dimensions by 5mm |
||
Profiles |
||
(L) 60 x 40mm |